A4 Conference proceedings

Variable Speed Drive-Based Fan Impeller Contamination Build-Up Detection:
Industrial Case Study


Publication Details
Authors: Tamminen Jussi, Ahonen Tero, Ahola Jero, Pöyhönen Santeri, Tiainen Toni
Publication year: 2015
Language: English
Related Journal or Series Information: European Conference On Power Electronics And Applications
Title of parent publication: 17th European Conference on Power Electronics and Applications (EPE'15-ECCE Europe)
ISSN: 2325-0313
JUFO-Level of this publication: 1
Open Access: Not an Open Access publication

Abstract
Contamination build-up can be considered as a root cause for the imbalance of the fan impeller. This contamination build-up can be detected without sensors by using a variable speed drive. In this paper, the use of the contamination detection method in the case of a rotational speed controlled industrial fan is examined.

Last updated on 2017-22-03 at 14:02